BUILDINGS OTHER THAN DWELLINGS COMPLIANCE
Approved Document L1 Volume 2 Conservation of Fuel and Power.
Document L1 Volume 2 is a complex document giving guidance for buildings other than dwellings (commercial, industrial, educational, etc.) that are:
- Extended
- Refurbished
- Renovated
- Undergo a Material Change of use
- Have a Change of Energy Status as a result of a new or extended heating, ventilation or air conditioning systems.
HIBEC understand the complexities of ADL1 Volume 2 and the difference between the three possible routes to compliance:
Route 1
The use of the ADL1 Volume 2 tables
The use of the tables given in ADL1 Volume 2 for:
- the area of glazing permitted
- the minimum U values of new and refurbished thermal elements (i.e. walls, floors and rooves)
- the minimum U values of controlled fittings (i.e.windows, doors and roof lights)
- the minimum standards of controlled services in compliance with the tables.
Route 2
The Use of Area Weighted Average U Values
A more flexible method of compliance for when an existing thermal element cannot be upgraded.
The reduction in energy efficiency performance from the un-upgradable element can be compensated for by upgrading beyond the minimum table value another thermal element.
Route 3
Whole Building Calculation Method using SBEM calculation
This method allows for maximum flexibility where un-upgradable elements, poor controlled services or glazing areas in excess of the minimum allowed are required.
HIBEC can analyse your specification and advise o the simplest and most cost effective route to compliance undertaking the calculations and writing the report for submission to the Building Control Officer as required.
Limiting the effects of Solar Gain in the Summer
The amount of glazing permitted in new non domestic buildings has been severely limited in order to reduce the need or installed load demand for air conditioning.
In essence, for side lit buildings all occupied and/or air conditioned rooms are allowed the equivalent of 1m height of east facing window around the room’s external perimeter at a solar transmittance of the glass of 0.68 and a window frame factor of 10%.
There are similar rules for top lit buildings with roof lights, where for buildings up to 6m height the area of roof lighting is 10% glazed at a frame factor of 25% and a solar transmittance of 0.68.
For buildings over 6m height the area of roof lighting is 20% glazed at a frame factor of 15% and a solar transmittance of 0.46.
HIBEC are aware that Architects try and maximise daylight in new buildings and that these equivalent areas are restrictive. Consequently we advise all architects and developers to undertake the SBEM as early as possible to ensure that the buildings glazing meet the requirements of ADL1 Volume 2.
HIBEC can advise you on meeting the requirements, be it reducing glass g values, adding shading or by using appropriate SBEM software that models external objects giving additional solar gain relief.
We have developed our own solar overheat spreadsheet calculation to determine if a room overheats without the need to set up the whole building in the SBEM.
If you would like a copy of our spreadsheet, please contact us, we would be pleased to share it with you.