Domestic Air Tightness Testing
HIBEC undertake domestic Air Tightness Testing (ATT) using our own calibrated equipment.
Also sometimes referred to as Air Pressure Testing, the test is an integral part of the ADL1 Volume 1 Dwellings compliance process.
The as designed SAP sets the target for the ATT, we test the dwellings ATT and the result is inserted in the as built SAP for immediate issue to the Building Control Officer for sign off.
The air test itself uses a fan within a frame that is set into the dwellings front door aperture which extracts air from the dwelling to create a slight 50 pa depressurisation of the building.
Whilst the dwelling is maintained at a set pressure, the amount of air being extracted is measured, which equates to how much air is coming into the building from cracks, holes and unwanted apertures.
The rate of air ingress and the internal dwelling surface area are used to express the result in terms of m3/hour /m2 at 50pa pressure.
The exercise is done to find and minimise the unwanted ingress points which are usually the source of drafts, such as poor fitting windows etc, which we can detect with the use of smoke pencils.
Less drafts means less energy lost, a more comfortable environment and happy new dwellings owners.
We offer a fast and efficient service and as qualified CIBSE Low Carbon Consultants, we are able to advise on suitable recommendations and improvements.
With the recent introduction of the Minimum Energy Efficiency Standards 2018 where rented property must achieve a minimum EPC rating of E, we are able to undertake pre EPC assessments and advise on the most cost effective way of improving buildings which are F & G rated.